亚洲 都市 校园 激情 另类,欧美精产国品一二三产品区别,无人在线观看高清电影电视剧,熟女乱p网



Search
產(chǎn)品分類
Machine equipment for transformer
Special equipment for transformer
點擊圖片可看完整大圖
 詳細介紹:

 

Description:

Outline 

      
SG series three-phase dry type isolation transformer factory in the light of the international similar products, based on the situation of China's development and production of a new generation of energy-saving power transformers from 300VA to 1600KVA, which meets IEC439, GB5226 and other international, national standards, winding entire column with bodiless way around the system; transformer vacuum dipping to transformer insulation class F or H grade to grade, to achieve advanced levels of performance. SG series three-phase dry type isolation transformers are widely used in AC 50Hz to 60Hz, below 660V voltage circuits, widely used in the import key equipment, precision machine tools, machinery and electronic equipment, medical equipment, rectifiers, lighting and so on. Of input and output voltage level, joint group and tap the number and location (typically ± 5%), winding capacity allocation, single-phase windings with the secondary, the use of rectifier circuit, is required with shell, etc., can be based on user demands meticulous design and manufacturing. 

+ Features 
       
Isolation transformer in a new center line - you can lift the power ground common mode interference and other troubled middle, isolation transformer will be three-to four-wire conversion △ Yo wiring system, plus shielded from the transformer to further Mianchu the internal coupling of high-frequency pulse interference and noise, although shielded isolation transformer to the interference of various NG (pulse and high frequency noise) can effectively prevent, but the transformer must be correctly and properly grounded, very strict, otherwise the resistance will be no effect of common mode interference. The company can design and produce high-quality customer isolation transformer. 
+ Feature advantages: 
Ø a high degree of isolation 
Ø N-G in good 
Ø a high degree of common mode interference rejection 
Ø will be converted to Y or △ △ Y to 
Ø easy to convert voltage tap 
Ø special performance by the user to design 

+ Technical indicators 
1 Input Voltage: 380V or 380V single-phase or single phase 220V 
2 Operating frequency: 50Hz-60Hz 
3 Efficiency: ≥ 95% 
4 Temperature rise: <60 
5 Waveform distortion: <0.1% 
6 High Voltage Test: 2500V, 1 minutes at zero breakdown 
7 Insulation resistance: winding-to-ground insulation resistance ≥ 500M Euro 
Primary on the secondary insulation resistance ≥ 500M Euro 
+ Use 
1 to altitude: ≤ 5000m 
2 Ambient temperature: -15 ℃ ~ +45 ℃ 
3 Relative humidity: ≤ 90% 
4 installation sites should not seriously affect the strength of transformer insulating gas, steam, chemical deposition, dirt, dust, and no other explosive conductive flammable corrosive substances. 
5 who do not meet the above conditions of use shall be determined in consultation with us. 
+ Isolation transformer installed in the application of power supply 
First, access the power input isolation transformer (Delta / Star) 
1, if the third harmonic and the interference signal power is quite serious, with △ / Yo isolation transformer, you can remove the third harmonic and reduce the interference signal. 
2, can be used △ / Yo isolation transformer to generate new neutral line, so that equipment has nothing to do with the power neutral line, avoid the bad result in the neutral network equipment does not run properly. 
3, non-linear load current waveform distortion caused (such as third harmonic) can be isolated without contamination grid. 
Second, access to the power output isolation transformer (star / triangle) 
1, to prevent the non-linear load current distortion, affecting the power supply back to normal work and anti-grid, played the role of clean power. 
2, the distortion effects of nonlinear load current sampling accuracy can Yo / △ isolation transformer input sampling, be able to respond to the actual situation of the control signal to control the normal power supply. 
3, if the load imbalance, with Yo / △ not affect the normal operation of power supply.

Links
上海英施丹電器設(shè)備制造有限公司百科信息 英施丹電器 
Copyright © 2012-2024 

Shanghai YingShiDan Electrical Manufacturing Co., Ltd.
National Toll Free Hotline :400 -0089-078 Phone 021 -61,556,622 Fax 021 -59580838 Contact: Mr. Tian

 
国产乱子伦精品免费女| 免费欧洲毛片A级视频| 中文字幕乱偷无码AV先锋蜜桃| 97色图片| 密桃麻豆WWW久久国产精品| 十八禁男女猛烈拍拍拍无遮挡|