SCB10-315KVA/400KVA/500KVA/630KVA800KVA1000KVA干式電力變壓器多少錢一臺(tái)¥什么價(jià)格 一、概述Summary 干式變壓器是一種鐵芯和繞組不浸于絕緣液體中的變壓器。本公司生產(chǎn)的環(huán)氧樹脂澆注干式變壓器產(chǎn)品按IEC國際標(biāo)準(zhǔn)和現(xiàn)行國家標(biāo)準(zhǔn)進(jìn)行設(shè)計(jì),其制造技術(shù)先進(jìn),具有低損耗、低局放、低噪音的安全、環(huán)保型產(chǎn)品。 The dry type transformer is a transformer with an iron core and winding not immersed in the insulating liquid. The company produced epoxy resin casting dry type transformer designs according to IEC international standards and the current national standards, advanced manufacturing technology. It’s safety and environmentally friendly products with low loss, low power, low noise. 二、標(biāo)準(zhǔn)Standards IEC 60076-11 GB 1094.11 GB/T 10228
三、型號(hào)含義Type Meaning
四、技術(shù)參數(shù)Technical Specification
10kV級(jí)SC(B)型干式變壓器技術(shù)參數(shù) Technical Specification of SC(B) type dry-type transformer with 10kV
額定容量 Rated Power (kV•A) | 電壓組合 Voltage Combination | 聯(lián)結(jié)組別 Connection Symbol | 空載損耗 No-load Loss (W) | 負(fù)載損耗 load Loss (W) (F)(120℃) | 空載電流No-load Current (%) | 短路阻抗Short- circuit Impedance (%) |
| 高壓HV (kV) | 高壓分接范圍Tapping Range of HV (%) | 低壓LV (kV) |
| 10型 10Type | 11型 11Type | 12型 12Type |
| 30 | 6 6.3 6.6 or 10 10.5 11 | ±2×2.5 or ±5 | 0.4 | Dyn11 or Yyn0 | 190 | 170 | 150 | 710 | 2.0 | 4.0 |
| 50 | 270 | 240 | 215 | 1000 | 2.0 |
| 80 | 370 | 330 | 295 | 1380 | 1.5 |
| 100 | 400 | 360 | 320 | 1570 | 1.5 |
| 125 | 470 | 420 | 375 | 1850 | 1.3 |
| 160 | 540 | 480 | 430 | 2130 | 1.3 |
| 200 | 620 | 550 | 495 | 2530 | 1.1 |
| 250 | 720 | 640 | 575 | 2760 | 1.1 |
| 315 | 880 | 790 | 705 | 3470 | 1.0 |
| 400 | 980 | 880 | 785 | 3990 | 1.0 |
| 500 | 1160 | 1040 | 930 | 4880 | 1.0 |
| 630 | 1340 | 1200 | 1070 | 5880 | 0.85 |
| 630 | 1300 | 1170 | 1040 | 5960 | 0.85 | 6.0 |
| 800 | 1520 | 1360 | 1210 | 6960 | 0.85 |
| 1000 | 1770 | 1590 | 1410 | 8130 | 0.85 |
| 1250 | 2090 | 1880 | 1670 | 9690 | 0.85 |
| 1600 | 2450 | 2200 | 1960 | 11700 | 0.85 |
| 2000 | 3050 | 2740 | 2440 | 14400 | 0.68 |
| 2500 | 3600 | 3240 | 2880 | 17100 | 0.68 |
|
注:表中數(shù)據(jù)僅供參考,公司保留數(shù)據(jù)變動(dòng)的權(quán)力,并接受特殊訂貨。 Sample data is for reference only. The company reserves the right to change the data, and to accept special orders.
20kV級(jí)SC(B)系列干式變壓器技術(shù)參數(shù) Technical specification of 20kV SC(B) type dry-type transformer
額定容量Rated Power (kV•A) | 電壓組合 Voltage Combination | 聯(lián)結(jié)組別 Connection Symbol | 空載損耗 No-load Loss (W) | 負(fù)載損耗 load Loss (W) (F)(120℃) | 空載電流No-load Current (%) | 短路阻抗 Short- circuit Impedance (%) | 高壓HV (kV) | 高壓分接范圍Tapping Range of HV (%) | 低壓LV (kV) | 50 | 20 22 24 | ±2.5 ±5 | 0.4 | Dyn11 Yyn0 | 340 | 1230 | 2.0 | 6.0 | 100 | 540 | 1990 | 1.8 | 160 | 670 | 2470 | 1.5 | 200 | ±2×2.5 ±5 | 730 | 2940 | 1.5 | 250 | 840 | 3420 | 1.3 | 315 | 970 | 4080 | 1.3 | 400 | 1150 | 4840 | 1.1 | 500 | 1350 | 5790 | 1.1 | 630 | 1530 | 6840 | 1.0 | 800 | 1750 | 8260 | 1.0 | 1000 | 2070 | 9780 | 0.85 | 1250 | 2380 | 11500 | 0.85 | 1600 | 2790 | 13800 | 0.85 | 2000 | 3240 | 16300 | 0.7 | 2500 | 3870 | 19300 | 0.7 |
注:表中數(shù)據(jù)僅供參考,公司保留數(shù)據(jù)變動(dòng)的權(quán)力,并接受特殊訂貨。 Sample data is for reference only. The company reserves the right to change the data, and to accept special orders.
五、外形尺寸圖Overall Dimension Drawing 10kV級(jí)SC(B)型干式變壓器外形尺寸圖 Overall dimension drawing of 10kV SC(B) type dry-type transformer |
| 額定容量 Rated Power (kVA) | 尺 寸 Overall Dimension (mm) |
| L | W | H | L* | W* | e | f | g |
|
| 160 | 1500 | 1200 | 2200 | 550 | 660 | 930 | 263 | 330 |
| 200 | 1500 | 1200 | 2200 | 550 | 660 | 940 | 268 | 338 |
| 250 | 1500 | 1200 | 2200 | 550 | 660 | 950 | 273 | 344 |
| 315 | 1500 | 1250 | 2200 | 550 | 660 | 960 | 278 | 350 |
| 400 | 1600 | 1300 | 2200 | 550 | 820 | 970 | 285 | 355 |
| 500 | 1700 | 1350 | 2200 | 660 | 820 | 985 | 295 | 360 |
| 630 | 1700 | 1350 | 2200 | 660 | 820 | 992 | 313 | 377 |
| 800 | 1800 | 1400 | 2200 | 820 | 820 | 1039 | 343 | 388 |
| 1000 | 1900 | 1400 | 2200 | 820 | 820 | 1109 | 351 | 391 |
| 1250 | 1900 | 1500 | 2200 | 820 | 820 | 1177 | 363 | 425 |
| 1600 | 2100 | 1700 | 2200 | 820 | 820 | 1535 | 323 | 390 |
| 2000 | 2300 | 1700 | 2300 | 1070 | 1070 | 1650 | 340 | 410 |
| 2500 | 2300 | 1700 | 2400 | 1070 | 1070 | 1780 | 360 | 430 |
|
注:提供的外形尺寸僅為設(shè)計(jì)選型時(shí)參考,最終尺寸以產(chǎn)品實(shí)際尺寸為準(zhǔn)。 Note:The overall dimension is only for reference.
品介紹 35kV級(jí)SC(B)10干式變壓器用于將20kV電網(wǎng)電源直接降低為400V配電電源或10kV輸電電源為用戶供電。由于具有諸多顯著優(yōu)點(diǎn),為越來越多的工程所采用。 執(zhí)行標(biāo)準(zhǔn) GB6450-1986干式電力變壓器 GB/T10228-1997干式電力變壓器技術(shù)參數(shù)和要求 GB/T17211-1998干式電力變壓器負(fù)載導(dǎo)則 GB1094.3-2003電力變壓器第3部分:絕緣水平、絕緣試驗(yàn)和外絕緣空氣間隙 JB/T10088-2004 6~500KV級(jí)電力變壓器聲級(jí) JB/T56009-1998干式電力變壓器產(chǎn)品質(zhì)量分等 35kV級(jí)SC(B)10干式變壓器主要優(yōu)點(diǎn)有: 1、減少占地和多級(jí)變電工程建設(shè),具有顯著的社會(huì)效益。 2、節(jié)省工程投資,提高經(jīng)濟(jì)效益。 3、減少10kV輸變電環(huán)節(jié),使運(yùn)行維護(hù)費(fèi)用明顯降低。 4、采用高壓小電流代替低壓大電流輸電,減少線路損耗,降低線路運(yùn)行成本。 5、20kV電源直接進(jìn)入用電中心,有效提高供電的可靠性。 35kV級(jí)SC(B)10干式變壓器產(chǎn)品特點(diǎn): 1、高性能、低損耗,為9型系列的換代產(chǎn)品。 2、選用優(yōu)質(zhì)硅鋼片,同時(shí)大幅降低磁通密度,減小運(yùn)行中硅鋼片磁致伸縮量,有效降低噪音。 3、優(yōu)化高壓線圈結(jié)構(gòu),改善了層間電壓和電容的分布,大大提高了產(chǎn)品耐受大氣過電壓和操作過電壓的沖擊能力,同時(shí)也改善了電場(chǎng)分布,使產(chǎn)品局放量進(jìn)一步降低。 4、可配置溫控系統(tǒng)和風(fēng)冷裝置,在負(fù)荷過大時(shí)自動(dòng)啟動(dòng)風(fēng)機(jī)冷卻裝置,有效提高設(shè)備過負(fù)荷能力。 35kV級(jí)SC(B)10干式變壓器技術(shù)參數(shù)
型號(hào) TYPE | 聯(lián)結(jié)組標(biāo)號(hào) | 電壓組合(KV) | 空載電流 % | 空載損耗 W | 負(fù)載損耗 W(120℃) | 短路阻抗 % | 高壓KV | 高壓分接范圍% | 低壓KV | SCB10-315/35 | Yyn0 或 Yd11 | 35 或 38.5 | ±5% 或 2×2.5% | 0.4 3.15 6 6.3 10 10.5 11 | 2 | 1160 | 4170 |
| SCB10-400/35 | 2 | 1360 | 5360 |
| SCB10-500/35 | 2 | 1600 | 6590 | 6 | SCB10-630/35 | 1.8 | 1840 | 7680 |
| SCB10-800/35 | 1.9 | 2220 | 9350 |
| SCB10-1000/35 | 1.9 | 2640 | 10880 | 7 | SCB10-1250/35 | 1.7 | 3090 | 12840 |
| SCB10-1600/35 | 1.7 | 3650 | 15390 |
| SCB10-2000/35 | 1.5 | 4200 | 18110 | 8 | SCB10-2500/35 | 1.5 | 4800 | 21680 |
| SCB10-3150/35 | 1.3 | 5000 | 24400 |
| SCB10-4000/35 | 1.3 | 6950 | 29330 | 9 | SCB10-5000/35 | 1.1 | 8320 | 34770 |
| SCB10-6300/35 | 1.1 | 9840 | 40630 |
| SCB10-8000/35 | Yd11 或 Ynd11 | 1 | 11200 | 45050 |
| SCB10-10000/35 | 1 | 12800 | 51200 | 7 | SCB10-12500/35 | 0.9 | 16150 | 55300 | SCB10-16000/35 | 0.8 | 19560 | 59800 |
|